The alarms on the ceiling can feel like a small detail next to everything else you sort as a landlord. They are not. Since the rules were updated in October 2022, there is a clear duty on landlords in England around smoke and carbon monoxide alarms, and a council can fine you up to £5,000 per property if you get it wrong. It is worth a few minutes to check yours are right.
Smoke alarms: one on every floor
The rule itself is simple. You need at least one smoke alarm on every storey of the property that someone uses as living space. A hallway and a landing are the obvious spots, but the bit landlords miss is the odd room, like a loft that has become a bedroom or a basement someone uses as a study. If people live, sleep or cook on that floor, it needs an alarm.
Alarms usually go on the ceiling, out in the circulation space such as a hall or landing, because that is where smoke travels first. Fitting them tight into a corner or right beside a kitchen or bathroom tends to cause false alarms, so placement does matter.
Carbon monoxide alarms and the 2022 change
This is where the rules got wider. You now need a carbon monoxide alarm in any room with a fixed combustion appliance, so a gas boiler, a wood burner or an open fire. Gas cookers are the one exception. Before 2022 the duty only covered solid fuel like a coal fire, so plenty of properties with gas boilers were technically fine then and are not now.
A CO alarm wants to sit at head height, roughly one to three metres from the appliance. Too close and it nuisance-trips, too far and it reacts slowly.
Checking they work at the right time
Here is the timing that catches people out. On the first day of a new tenancy, you have to make sure every alarm is working. Not last month, not “it was fine when we fitted it”, but on the day the tenant moves in. After that, the tenant is expected to test them during the tenancy, and if they tell you one has stopped working you need to repair or replace it as soon as you reasonably can.
Keep a note of that start-of-tenancy check. If a dispute ever comes up, a dated record is worth a lot.
Battery or mains wired?
The regulations let you use either, as long as the alarm actually works, so battery-only units are legal. That said, sealed ten-year alarms and mains-wired interlinked systems are far more reliable. There is no flat battery to worry about, and when they are linked, one going off sets them all off. In a house of multiple occupation the bar is higher again, and building standards usually point you towards mains interlinked alarms on a proper grade of system.
Where landlords tend to slip up
- Leaving it to the tenant’s own plug-in alarm, which you have no control over
- Fitting nothing on a loft or cellar floor that is actually lived in
- No carbon monoxide alarm in the room with the boiler
- No record that the alarms were tested when the tenancy started
If you are not sure your setup matches the current rules, it helps to have an electrician look at where the alarms sit and whether interlinked mains units make sense for your property. We cover this as part of our work with landlords across Liverpool and the North West, and you can read more about our fire alarm testing as well.
Common questions
Do smoke alarms have to be mains wired in a rented house?
Not for a standard single let. The law asks for a working alarm on each living storey, and battery units are allowed. Mains interlinked alarms are the safer bet and are often expected in HMOs, but for an ordinary house or flat the choice is yours as long as they work.
Who tests the alarms once someone has moved in?
That falls to the tenant during the tenancy. Your job is to have them working on day one and to fix any alarm the tenant reports as faulty. It is sensible to remind tenants to test monthly, since a dead alarm helps nobody.
What happens if I ignore it?
The council can serve a remedial notice, and if you do not act they can fine you up to £5,000 for that property. More to the point, working alarms are what give people the seconds they need to get out.
What this guide is based on
The standards, rules and job records behind the figures above.
- The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. The five year inspection duty and the 28 day rule for giving tenants a copy of the report.
- The Renters’ Rights Act 2025. Lifted the maximum civil penalty for breaching those standards from £30,000 to £40,000 per breach from November 2025.
- BS 7671:2018+A2:2022. The wiring regulations every inspection is coded against, so C1, C2 and C3 mean the same thing whoever carries out the test.
- HMO licence conditions across Liverpool and the surrounding councils. What the licensing team asks for at inspection, which is usually the logbook and the last certificate.
- Our own job records across Liverpool and Merseyside. The figures above come from work we have actually priced and carried out, not from a national average.
Checked on 5 July 2026 by Dave Harvey, NAPIT approved contractor, member 66463. Rules change, so if you are reading this a long way after that date, give us a ring and we will tell you where it stands.
Related reading
How Long Does an EICR Take?
Usually two to four hours for a normal house. But that range hides a lot, and if you are planning a void…
Landlords
How Much Does an EICR Cost? A 2026 Guide for Landlords
Ask three electricians what an EICR costs and you will get three different answers. That is not because anyone is being cagey,…
Landlords
Is PAT Testing a Legal Requirement for Landlords?
This one causes more confusion than almost anything else in landlord compliance, and the reason is that the honest answer is not…
The work behind it
Landlord Electricians
EICRs, fire alarm testing and emergency lighting for rented property across Liverpool, booked around your tenants and certified the same week.
Electrical Inspection & Testing
Full Electrical Installation Condition Reports for landlords, homeowners and businesses, with the certificate issued within 24 hours and remedials priced up front.
HMO Electricians
The full set of certificates a licensed HMO needs, from the EICR to the alarm and emergency lighting records the council asks to see.